Commit 04ff9ab1 authored by Graeme Russ's avatar Graeme Russ Committed by Wolfgang Denk
Browse files

Fix sc520 timer interrupt generation


The current implementation has the timer being started before the interrupt
handler is installed. It the interrupt occurs before the handler is
installed, the timer interrupt is never reset and the timer stops

Signed-off-by: default avatarGraeme Russ <graeme.russ@gmail.com>
parent f3a8d6b2
No related merge requests found
......@@ -54,9 +54,6 @@ int timer_init(void)
write_mmcr_word (SC520_GPTMR1MAXCMPA, 100);
write_mmcr_word (SC520_GPTMR1CTL, 0xe009);
/* Clear the GP Timers status register */
write_mmcr_byte (SC520_GPTMRSTA, 0x07);
/* Register the SC520 specific timer interrupt handler */
register_timer_isr (sc520_timer_isr);
......@@ -64,6 +61,9 @@ int timer_init(void)
irq_install_handler (0, timer_isr, NULL);
unmask_irq (0);
/* Clear the GP Timer 1 status register to get the show rolling*/
write_mmcr_byte (SC520_GPTMRSTA, 0x02);
return 0;
}
......
0% Loading or .