serial: pl01x: fix pl011 baud rate configuration
UART_IBRD, UART_FBRD, and UART_LCR_H form a single 30-bit wide register which is updated on a single write strobe generated by a UART_LCR_H write. So, to internally update the content of UART_IBRD or UART_FBRD, a write to UART_LCR_H must always be performed at the end. Signed-off-by:Vikas Manocha <vikas.manocha@st.com> Acked-by:
Simon Glass <sjg@chromium.org>